Throttling device list
Model and indicating methods of the throttling device
Standard orifice plate and ISA1932 nozzle
Long radius nozzle
 Venturi tube
Air foil type volume measuring device
Two-tier Venturi tube and Plugging Type Flowmeter with Low Pressure Loss
Uniform Velocity Pipe(Annubar flowmeter)
1/4Round Orifice Plate Fastigiate Entry Orifice Plate and two-tier orifice plate
Segmental Orifice Plate with Excenric Orifice Plate
Integer Small Orifice Plate,inner Small Orifice Plate
High-pressure Lens Washer Orifice Plate
The pipe sundry components for steam-power plant
The accessories of throttling device


The accessories of throttling device
Condenser
   In order to avoid the high-temperature media damaging the differential pressure transmitter,the condenser shall be installed at the connecting pipe between the throtting device and the differential pressure transmitter for the purpose of protecting the differential pressure transmitter.
(1)Models and Application Range:
Model
Application Range
FL-6.4
Pressure≤6.4Mpa
FL-10
Pressure≤10.0Mpa
FL-20
Pressure≤20.0Mpa
FL-30
Pressure≤30.0Mpa
(2)Structure Form:(shown as the right picture)

Seal pod
   In order to avoid the caustic media damaging the differential pressure transmitter,the seal pod shall be installed at the connecting pipe between the throttling device and the differential pressure transmitter for the purpose of protecting the differential pressure transmitter.
   FG-A Type is asopted when the medium weight is more than the weight of separating liquid
   FG-B Type is asopted when the medium weight is less than the weight of separating liquid
(1)Models and Application Range:
Model
Application Range
FG-6.4A
Pressure≤6.4Mpa
FG-10A
Pressure≤10.0Mpa
FL-6.4B
Pressure≤6.4Mpa
FL-10B
Pressure≤10.0Mpa
(2)Structure Form:(shown as the right picture)

Gas ohamber,sediment
   When the measured media is liquid,in order to aviod influencing the measurement caused by the existing gas in the guided pressure pipe,generally the gas chamber shall be installed at the top of the guide pressure pipeline,so as to drain the gas in the guided pressure pipeline periodically and attain to the purpose of increasing the measuring accuracy.
   When the measured media is gas,in order to avoid influencing the measurement caused by the exising liquid in the guided pressure pipe,generally the sediment shall be installed at the top of the guided pressure pipeline,so as to drain the liquid in the guided pressure pipeline periodically and attain to the purpose of increasing the measuring accuracy.
(1)Models and Application Range:
Model
Application Range
FJ-6.4
Pressure≤6.4Mpa
FJ-10
Pressure≤10.0Mpa
FC-6.4
Pressure≤6.4Mpa
FC-10
Pressure≤10.0Mpa
(2)Structure Form:(shown as the right picture)

Balancer
   When measuring the liquid levels of the open-top container or the low-pressure container,thesinglelayer balancer shall be adopted.
   When measuring the top water-level of the boiler,the double-layers balancer shall be adopted.
(1)Models and Application Range:
Model
Name
Application Range
FP6.4A
single-layer balancer
Pressure≤6.4Mpa
FP-20A
single-layer balancer
Pressure≤20.0Mpa
FP-32B
single-layer balancer
Pressure≤32.0Mpa
FP-6.4B
double-layer balancer
Pressure≤6.4Mpa
FP-25B
double-layer balancer
Pressure≤25.0Mpa
(2)Structure Form:(shown as the right picture)